2. 
Connecting to the Dataport Command Interface through the 
RS-232 port. 
The RS-232 port is a 9-pin, female, D-sub connector located on the back of the GW. The port 
is configured as a DCE (Data Communications Equipment). The RS-232 port is default set to 
9600 baud, 8 databits, none parity and 1 stopbit from factory. The RS-232 port is also referred 
to as the Dataport. 
2.1. 
Hardware And Cabling 
The pin outs for the RS-232 are defined in the following table (the DTE, Data Terminal 
Equipment, could be a PC or other device capable of serial communication). 
 
Pin no 
Signal 
Description 
Direction 
CD 
Carrier detect 
To DTE 
2 RD 
Receive 
data 
To 
DTE 
3 TD 
Transmit 
data 
From 
DTE 
DTR 
Data terminal ready 
From DTE 
5  
Ground 
 
DSR 
Data set ready 
To DTE 
RTS 
Ready to send 
From DTE 
CTS 
Clear to send 
To DTE 
RI 
Ring indicator 
To DTE 
 
NOTE! A straight through cable should be used between the TANDBERG GW’s RS-232 port 
and the DTE. 
The figure below illustrates the recommended cable-wiring scheme for connecting the GW to 
a PC through RS-232. 
 
 
DTR and RTS are ignored. DSR, CD, and CTS are always asserted, while RI is not used.
 
 
TANDBERG GW 
PC 
 
DCE, 9 pin 
DTE, 9 pin 
 
 1 CD 
 
  1 CD 
 2 RD 
 
  2 RD 
 3 TD  
  3 TD 
 4 DTR 
  4 DTR 
 5 GND 
  5 GND 
 6 DSR 
  6 DSR 
 7 RTS 
  7 RTS 
 8 CTS 
  8 CTS 
 9 RI  
  9 RI