EXP Computer S200 用户手册

下载
页码 162
Bridging 
115
T0008-16F
Release 5.2M
Mixed LAN Operation
Steps to Configure 
Mixed LAN 
Bridging Operation
To perform mixed LAN bridging operation in a PathBuilder S24x, 26x, and 27x 
switch, configure a unique bridge link and router interface number for each LAN 
interface from the Port record. You must also configure the WAN bridge link to sup-
port Transparent Bridging and Source Route Bridging.
Follow these steps to configure Mixed LAN Bridging, as shown in Figure 54.
Step
Action
Result/Description
1
Make a local CTP connection to a 
PathBuilder S24x, 26x, and 27x 
switch.
The CTP is physically connected to 
the device you are configuring.
2
Select Configure -> Port. from the 
CTP Main menu.
The Port record appears.
3
Configure the Port record as you 
normally do for an Ethernet LAN 
connection.
Two new parameters, 
Bridge Link 
Number
 and 
Router Interface
appear in the record. 
4
At the Bridge Link Number: 
parameter, type in a number 1-4 to 
identify the bridge link, and press 
Return. 
For example, you can configure the 
Ethernet port as bridge link #1. 
Note
The default value for this 
parameter is 1.
This matches this port 
configuration to a specific bridge 
link number within the bridging 
configuration. If the bridge link 
you select is already used, a 
warning message appears, but your 
input is retained in the CMEM.
5
At the Router Interface Number: 
parameter, type in a number 1-4 to 
identity the router interface.
For example, you can configure the 
Ethernet port as router interface #1. 
The default value for this 
parameter is 1.
This matches this port 
configuration to a router link 
number within the router 
configuration. If the router 
interface number you select is 
already used, a warning message 
appears, but your input is retained 
in the CMEM.
6
Typeand press Return to save the 
record.
This saves the record.
7
Perform a Node boot from the Boot 
menu.
This implements your changes, but 
if you want the new bridge link to 
be active, you must configure the 
Bridge Link record under the 
Configure Bridge menu. Go to the 
following step. By default, the 
bridge link is not activated until 
you activate it.
8
Select 
Configure Bridge -> 
Bridge Link Parameters 
from 
the CTP Main menu, to activate the 
bridge link.
The Bridge Link Parameters menu 
appears.