EXP Computer S200 用户手册

下载
页码 162
36 
Bridging
Configuring the PathBuilder S200 Series Switch for Bridging Operation
Increasing the frame size also causes the reduction in frame overhead. If a 1000 byte 
data packet required a 50 byte header (frame + IP + TCP), then if 2000 bytes were 
placed in the frame with the same frame, the difference in overhead is 50/1000 = 5% 
versus 2.5%. As the size of the data increases, the overhead becomes even less. 
However, at these levels, the gain is marginal. Other factors may reduce this method 
of gain considerably. For example, intermediate systems have a limit on how large a 
frame they can handle.
As the size of the frame becomes larger, there is a corresponding increase in the time 
the frame spends in transmission media. The error rate of transmission media is finite 
and becomes a problem when the time for transmitting a frame becomes long enough 
that the probability of an error occurring during the transmission time is likely. An 
error on a large frame with its subsequent retransmission means the media are used 
with unproductive transmissions and reduced efficiency.
Standard Frame 
Sizes
In general, these industry standards can be used as a guideline for selecting the 
maximum frame size.
Bridge Transit Time
The transit time for bridged traffic within a PathBuilder S200 series switch is fixed to 
an upper bound of approximately one second. If the time is exceeded, the frame is 
discarded. This avoids extra traffic being sent (especially due to LLC2 recovery 
procedures).
Duplicate frames will frustrate normal recovery procedures and cause extra traffic to 
be generated. When a frame is discarded in this manner, the port statistic in the 
Detailed Port Stat screen displays “Frames Discarded: Congestion.”
Max Frame Size
Line Speed Range (kbps)
512
9.6 to 38.4
1500
38.4 to 56
2052
56 to 1544
4472
1544