IMC Networks 6 用户手册

下载
页码 28
 
19
 
SNMP Management Module LEDs 
The SNMP Management Module features several LEDs.  The LED functions are: 
LNK/ACT 
 
FDX/COL 
 
TEMP 
 
PS 
 
FAN A / FAN B 
Glows green when a link is established on port.  
Blinks green when data activity occurs. 
Glows yellow when port is in Full-Duplex mode.  
Blinks yellow when port is operating in Half-
Duplex mode and collisions occur. 
Glows yellow when temperature of unit 
surpasses a user-defined level. 
Glows yellow when one power supply module 
malfunctions. 
Glows yellow when a fan malfunctions. 
 
DC Power Wiring, Replacing Power Supply Modules and Fans 
DC Power Supply Module Wiring Instructions 
The following diagram shows the wiring configuration for a -48 VDC power supply 
module for the iMediaChassis/3. 
 
 
 
NOTE 
Incorrect wiring will result in chassis malfunction. 
 
The iMediaChassis/3 is compliant with Isolated Grounding Plane practices.  The 
POSITIVE and NEGATIVE terminals are isolated from chassis ground and must have 
a ground reference at the power-sourcing equipment.