Chapter 26 – Maintaining The Router
The Threshold configures the threshold to compare with the shell command result to 
see whether the condition is true or false.
The And Repeats configures how many times the condition must be true before the 
alert is generated. 
The And Until configures how many seconds the condition should be true before an 
alert is generated.
The Not Cleared Repeats configures how many times the condition must be false 
before the alert is cleared.
The Not cleared Until configures how many seconds the condition must be false 
before an alert is cleared.
The Parameters for RMON table allows user to configure additional parameters if 
the alert definition entry type is RMON type.
The Device Name configures the name of the device to be monitored.
The MIB Variable configures the MIB variable being monitored.
The Sample Interval configures how often samples should be generated.
The Rising Threshold configures the value that will trigger an event when the value 
of the variable increments past this value.
The Falling Threshold configures the value that will trigger an event when the value 
of the variable decreases past this value.
The Startup configures the condition that will cause the initial event.
RuggedCom                                                                                                                                      239