RAD Data comm MBE10-8D 用户手册

下载
页码 58
MBE Family Installation and Operation Manual 
Chapter 4  Troubleshooting and Diagnostics 
 
Alarms and Troubleshooting 
4-3 
 
To filter the Debug Messages log: 
1.  In the Main menu, type 0 (Exit).  
The Operational Status Messages screen appears. 
2. Type DO (Debug Open).  
The Debug Messages screen appears. 
3. Type DH (Debug Help). 
A list of operational/connectivity categories appears. Each category has the 
values: Enable or Disable. An enabled item appears in the log, and a 
disabled item is not included. 
4.  To enable or disable items, type the number of the item and choose the 
appropriate value.  
Resetting MBE to Factory Settings 
You can reset MBE to the default factory settings. This is useful if you want to 
reconfigure MBE and remove previous configuration data. 
 
To reset the MBE to the factory settings: 
1.  In the Main menu, type 0 (Exit).  
The Operational Status Messages screen appears. 
2. Type DO (Debug Open) to perform the reset. 
The Debug Messages screen appears. 
3. Type SF (Set Factory) to perform the reset. 
 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com