Install Off-Premises Station Wiring
Issue 10 June 2005
133
 
Install Off-Premises Station Wiring
The cabling for off-premises stations is provided by the local telephone company. These 
stations can appear on any of the RJ21X network interfaces provided for the CO trunks. 
!
CAUTION:
CAUTION:
Use only an FCC-approved (or equivalent) analog type telephone (such as a 
2500-type) as an off-premises station. The TN746B and TN2183 Analog Line 
circuit packs can be connected to off-premises stations.
To wire off-premises stations:
1. Install an A25D cable between the RJ21X network interface and a sneak fuse panel. 
2. At the MDF, connect jumper wires between 1 row/connecting block in the green field and up 
to 3 rows/connecting blocks in the purple field to concentrate the analog line pairs.
3. Connect an A25D cable between the sneak fuse panel and the terminal block connector 
associated with the green row in Step 2.
4. Install a green label on the terminal block to identify the remote location. 
5. Administer per Administrator’s Guide for Avaya Communication Manager.
Install Off-Premises or Out-of-Building Stations
Out-of-building campus stations are those telephones not physically located in the same 
building as the equipment room but are located on the same property.
Analog Off-Premises Stations
connections for 1 to 8 off-premises analog telephones. Only analog telephones connected to 
TN746B, TN2183, or TN769 Analog Line circuit packs can be installed out-of-building.
The maximum distance from the system cabinet to the out-of-building voice terminal is 6000 
feet (1828.8 m) using 24 AWG (#5) (0.26 mm
2