Bay Technical Associates 5218H 用户手册

下载
页码 61
30
 
By responding to the Enter Request: message at the end of the main
configuration menu (see 
Section 6.1) with "4" (Set Data Block
Length), you may change the data block length used in Mode 6.
The multiport will respond with:
Current Block Length is...................032
Enter Block Length (1 to 250)............:
NOTE: 
Carriage Return is required after the new length.
Enter the block length that you desire, followed by 
Carriage Return.
For example, if you enter "
100" and Carriage Return, the multiport will
respond with:
Current Block Length is..................100
Save Changes Permanently? (Y/N):
If you answer "
Y" (yes), the new block length will be saved in
non-volatile memory, and the multiport will subsequently power-up at
that new length.  If you answer "
N" (no), the new data block length will
be stored in RAM and will be lost upon next power-up.  The multiport
will now return to the main configuration menu (see
Section 6.1).