38.3.2  Supported MIBs 
MIBs let administrators collect statistics and monitor status and performance.
The Switch supports the following MIBs:
• SNMP MIB II (RFC 1213)
• RFC 1157 SNMP v1
• RFC 1493 Bridge MIBs
• RFC 1643 Ethernet MIBs
• RFC 1155 SMI
• RFC 2674 SNMPv2, SNMPv2c
• RFC 1757 RMON
• SNMPv2, SNMPv2c or later version, compliant with RFC 2011 SNMPv2 MIB for IP, RFC 2012 
SNMPv2 MIB for TCP, RFC 2013 SNMPv2 MIB for UDP
38.3.3  SNMP Traps 
The Switch sends traps to an SNMP manager when an event occurs. The following tables outline the 
SNMP traps by category.
An OID (Object ID) that begins with “1.3.6.1.4.1.890.1.5.8” is defined in private MIBs. Otherwise, 
it is a standard MIB OID.
The OIDs beginning with “1.3.6.1.4.1.890.1.5.8.
68
” are specific to the MES3500-24 switch.
The OIDs beginning with “1.3.6.1.4.1.890.1.5.8.
57
” are specific to the MES3500-24F switch. 
Table 120   
SNMP System Traps 
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
coldstart
coldStart
1.3.6.1.6.3.1.1.5.1
This trap is sent when the Switch is turned 
on.
warmstart
warmStart
1.3.6.1.6.3.1.1.5.2
This trap is sent when the Switch restarts.
temperature
TemperatureEventOn
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
This trap is sent when the temperature goes 
above or below the normal operating range.
TemperatureEventClear
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
This trap is sent when the temperature 
returns to the normal operating range.
voltage
VoltageEventOn
1.3.6.1.4.1.890.1.5.8.68.27.2.1
1.3.6.1.4.1.890.1.5.8.57.27.2.1
This trap is sent when the voltage goes 
above or below the normal operating range.
VoltageEventClear
1.3.6.1.4.1.890.1.5.8.68.27.2.2
1.3.6.1.4.1.890.1.5.8.57.27.2.2
This trap is sent when the voltage returns to 
the normal operating range.