 Chapter 23 VLAN Stacking
MES3500-24/24F User’s Guide
183
23.4.1  Port-based Q-in-Q
Port-based Q-in-Q lets the Switch treat all frames received on the same port as the same VLAN 
flows and add the same outer VLAN tag to them, even they have different customer VLAN IDs.
Click Port-based QinQ in the Advanced Application > VLAN Stacking screen to display the 
screen as shown.
Figure 91   
Advanced Application > VLAN Stacking > Port-based QinQ 
The following table describes the labels in this screen. 
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these 
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save 
your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Table 57   
Advanced Application > VLAN Stacking (continued)
LABEL
DESCRIPTION
Table 58   
Advanced Application > VLAN Stacking > Port-based QinQ
LABEL
DESCRIPTION
Port
The port number identifies the port you are configuring.
SPVID
SPVID is the service provider’s VLAN ID (the outer VLAN tag). Enter the service provider ID (from 
1 to 4094) for frames received on this port. See 
 for more background 
information on VLAN ID.
Priority
Select a priority level (from 0 to 7). This is the service provider’s priority level that adds to the 
frames received on this port.
"0" is the lowest priority level and "7" is the highest.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these 
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save 
your changes to the non-volatile memory when you are done configuring.