Allied Telesis AR300 series 用户手册

下载
页码 8
3
If the interface is not activated, the reason could be one of the following: 
1.
The interface has been put into NT mode. 
On the AT-AR041 and AT-AR042 multi-BRI NSM modules it is possible to put the ISDN 
interface(s) into NT mode so that they can emulate a network switch interface. This can 
be useful for bench testing network configurations. To see which mode the ISDN interface 
is currently in, use the command:
show bri=n state
The first item in the output, Interface Type, will have either the value NT or the value TE. 
If the ISDN interface is in TE mode then it is set up correctly. 
If the ISDN interface is in NT mode it is set up incorrectly, and it is a matter of changing 
a pair of jumpers on the circuit board to put the interface back into TE mode. 
2.
There is a physical fault in the router's ISDN interface circuitry. 
The router is able to test its own interface. The steps to performing the self-test are:
a
Create a BRI loopback plug and insert it into the interface socket.
If the BRI interface under consideration is on an ICM card, it is not necessary to use a 
loopback plug, as the interface is capable of internal loopback, and so does not need 
external loopback. 
b
At the command prompt, enter the command:
enable test int=brin
where n is the number of the BRI interface under consideration. Interfaces are 
numbered from 0. 
This initiates a 4-minute self-test.
c
Wait 4 minutes, until the router outputs a message to inform you that the self-test is 
complete.
Then enter the command:
show test
which will output the test results as shown in the following figure.
If the Result column shows the result to be good, then the BRI interface has no physical 
faults (that the self-test can detect, anyway). If the result is anything other than good, 
then the interface is faulty and you need to contact your distributor regarding a repair.
Board      ID  Bay Nick Name       Part Name       Rev   Serial number
------------------------------------------------------------------------
Base       47      3100            NIQ-3100        M2-0  9774202
IC Module  39   0  ICM-BRI1        EXP-0303        M1-2  8620690
                                          Duration       Details
Interface  State    Result              Type  (minutes)  Data( %OK )  Control
------------------------------------------------------------------------
eth0    no test     -                  -           -    -     -      -
port0   no test     -                  -           -    -     -      -
port1   no test     -                  -           -    -     -      -
port2   no test     -                  -           -    -     -      -
port3   no test     -                  -           -    -     -      -
BRI0    complete  good                 -           4   good(100.0)   -
------------------------------------------------------------------------