Siemens SM2 monitoring system 用户手册

下载
页码 500
U3585-J-Z125-8-76
225
SM2 reports
CATEGORY WSET report
CATEGORY WSET-Report
Report output
The REPORT CATW statement is used to request the output of the CATEGORY WSET
report.
Monitoring information
This report contains the totals (SUM) for all categories in the first line following the table
header. The data for the individual categories (up to 16) is output in the following lines.
The columns contain the following data:
CATEGORY NAME
Task category designation
WS-ALL
PPC
Sum of the average planned page counts of all tasks in a category
UPG
Sum of the average used page counts of all tasks in a category
D016ZE04 SM2 CATEGORY WSET  CYCLE:  120 S  SAMPLES:   293    99-03-24  14:30:00
           |CATEGORY |    WS-ALL     |    WS-ACT     |    WS-WACT    |
           |  NAME   |  PPC  |  UPG  |  PPC  |  UPG  |  PPC  |  UPG  |
           +---------+-------+-------+-------+-------+-------+-------+
           | SUM     | 53579 |386151 |  8915 | 62377 |     0 |     0 |
           | SYS     |  5265 | 43006 |  3962 | 41027 |     0 |     0 |
           | DIALOG  |  2052 |  6901 |    56 |   148 |     0 |     0 |
           | BATCH   |   486 |  1352 |   146 |   478 |     0 |     0 |
           | TP      |  2430 |  3402 |  1839 |  2938 |     0 |     0 |
           | TP1     |  2101 |  4921 |   455 |  1181 |     0 |     0 |
           | BATCHDB |     0 |     0 |     0 |     0 |     0 |     0 |
           | BATCHF  |  1482 |  2611 |   463 |  1079 |     0 |     0 |
           | DIALOG1 | 38278 |311814 |   509 |  3382 |     0 |     0 |
           | DIALOG2 |   430 |  2498 |   430 |  2498 |     0 |     0 |
           | DIALOG3 |  1055 |  9646 |  1055 |  9646 |     0 |     0 |