Siemens SM2 monitoring system 用户手册

下载
页码 500
78
U3585-J-Z125-8-76
CHANGE-MEASUREMENT-PROGRAM
Statements for SM2 administrators
CHANGE-MEASUREMENT-PROGRAM
Stop current monitoring program run and restart it with new
monitored objects
Function
This statement is used to stop the current monitoring program run and restart it using newly
defined monitored objects/monitoring parameters. The current monitoring cycle is inter-
rupted.
Format
Operands
TYPE =
Specifies the type of monitoring program (the descriptions below are in alphabetical order)
to be restarted using the modified monitored objects/monitoring parameters.
TYPE = *BCAM-CONNECTION
The BCAM-CONNECTION monitoring program is restarted with new monitoring param-
eters or connection sets.
TYPE = *CHANNEL-IO
The CHANNEL-IO monitoring program is restarted with a new range of channels.
TYPE = *COSMOS
The COSMOS monitoring program is restarted with a new scope.
TYPE = *DISK
The DISK monitoring program is restarted with a new range of disks.
TYPE = *DISK-FILE
The DISK-FILE monitoring program is restarted with a new range of disks.
TYPE = *FILE
The FILE monitoring program is restarted with a new range of files.
CHANGE-MEASUREMENT-PROGRAM
              *ISAM / *PERIODIC-TASK / *RESPONSETIME / *SERVICETIME / *SYSSTAT / *TASK