Statements for SM2 administrators
MODIFY-RESPONSETIME-PARAMETER
MODIFY-RESPONSETIME-PARAMETER
Modify parameters for RESPONSETIME monitoring
Function
This statement is used to modify the RESPONSETIME monitoring program definition.
Format
Operands
SCOPE =
Defines whether recording of the response time data is to be bucket-specific or category-
specific.
SCOPE = *UNCHANGED
The scope defined by this time will not be changed.
SCOPE = *BUCKET
The response time data is to be recorded based on buckets.
SCOPE = *CATEGORY
The response time data is to be recorded based on categories.
MODIFY-RESPONSETIME-PARAMETER
,DEFINITION = *UNCHANGED / *1 / *2
,CONNECTION-NUMBER = *UNCHANGED / <integer 1..8187>
,THINKTIME-BUCKETS = *UNCHANGED / *STD-LIMITS / list-poss(5): <integer 1..99999>
,WAITTIME-BUCKETS = *UNCHANGED / *STD-LIMITS / list-poss(5): <integer 1..99999>