Alliance Laundry Systems NK120 用户手册

下载
页码 26
14
505942
 Installation
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
E. Connecting the Repeater 
to a Laptop
NOTE: If connecting the repeater to a laptop, a 
terminating resistor must be used. Refer to the 
section on “Interfacing a Laptop to Machines”
 on 
page 5. Refer to Figure 9
.
F. Tests
Once the network has been wired, run the 
following tests to ensure proper installation.
1. Power off all machines before test.
2. Check for continuity of 2 wires running from 
the central PC.
a. Disconnect the wires from the PC
b. Check for 120  
Ω
  ± 20%. A much higher 
reading indicates an open circuit. This is 
caused by a break in the network. A much 
lower reading indicates a short in the 
network, which means the network is only 
communicating to a certain point in the 
network.
To Connect Repeater to Laptop
Figure 9
COM1047N
NETWORK
CABLE
(210165)
TERMINAL
STRIP
WALL
ADAPTER
(120 VOLT)
NBS-20
CARD
BLACK
RED
BLACK
GREEN
12 VOLT
DC
REPEATER
NETWORK
CABLE
(210150)
RED
GREEN
BLACK
WHITE
120 
Ω
1/2 WATT 
TERMINATING
RESISTOR
RS-485
RED