Lamp Replacement
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or 
sooner if a noticeable degradation in brightness occurs. Contact your Runco dealer to 
obtain a replacement lamp.
1.
Turn off the projector and unplug the power cord. Allow the projector to cool down for 
approximately 45 minutes prior to removing the lamp assembly for replacement.
2.
Loosen the two captive Lamp Cover screws on the 
side of the projector and remove the cover.
 
 
 
 
 
 
 
 
 
 
 
3.
Remove the three Phillips round-head lamp 
assembly mounting screws. These are identified by 
arrows pointing to them on the lamp housing. 
4.
Grasp the lamp assembly handle and pull gently, 
removing the lamp module from the projector 
housing.
5.
Install the new lamp module. Secure it in place with 
the three screws that you removed in Step 3. 
6.
Replace the lamp cover and re-tighten the two 
Lamp Cover screws.
7.
Re-connect the AC power cord to the projector. 
8.
Reset the Lamp Hour counter. To do this, press and hold the ENTERDOWN and 
RIGHT buttons on the projector rear-panel keypad (see Figure 2-2) simultaneously. 
Then, press the ON button. When you do, “LAMP 0000H” appears on-screen to 
confirm the counter reset. 