Viking 855 用户手册

下载
页码 16
SECTION  TSM
685.2
ISSUE
C
PAGE  3 OF  16
fIGURE 3
RELIEf VALVE POSITION 
SPECIAL INfORMATION
ROTATIONViking Mag Drive®  pumps are designed to run  
in either direction. See 
PUMP ROTATION, page 11.
PRESSURE RELIEF VALVES:
1.  Viking pumps are positive displacement pumps and must 
be provided with some sort of pressure protection.  This 
may be a relief valve mounted directly on the pump, an 
inline pressure relief valve, a torque limiting device or a 
rupture disk. Do not rely on decoupling of magnets for 
protection from over pressure; this may result in damage 
to the magnets, pump, or other equipment.
2.  Relief valves are mounted as standard on the casing of 
AS, AK,AL,KE and KKE size pumps. 
3.  If the pump rotation is to be reversed during operation, 
pressure protection must be provided on both sides of 
the pump.
4.  The  relief  valve  adjusting  screw  cap  must  always 
point  towards  the  suction  side  of  the  pump. 
See 
figure  3.  If  the  pump  rotation  is  reversed,  remove 
the  pressure  relief  valve  and  turn  end  for  end 
(see 
PUMP ROTATION, page 11 for additional information. 
5.  Pressure relief valves cannot be used to control pump 
flow or regulate discharge pressure.
For additional information on pressure relief valves, refer to 
Technical Service Manual TSM000 and Engineering Service 
Bulletin ESB-31.
CAUTION !
Rare  earth  magnets  used  in  couplings  have 
extremely  strong  magnetic  fields  capable  of 
changing  performance  or  damaging  items 
such as the following:
 
Pacemakers
 
Metal Implants
 
Watches
 
Computers & disks
 
Credit Cards
Completely  assembled  magnetic  couplings 
will not affect items listed above – only disas-
sembled components.
There are no known harmful effects of these 
magnetic fields on the human body.
RELIEF VALVE ADJUSTING 
 SCREW CAP
SUCTION
DISCHARGE
DANGER !
Before opening any Viking pump liquid cham-
ber (pumping chamber, reservoir, relief valve 
adjusting cap fitting etc.) Be sure:
1. That any pressure in the chamber has been 
completely  vented  through  the  suction 
or  discharge  lines  or  other  appropriate 
openings or connections.
2. That  the  driving  means  (motor,  turbine, 
engine, etc.) has been “locked out” or made 
non- operational so that it cannot be started 
while work is being done on pump. 
3. That you know what liquid the pump has been 
handling  and  the  precautions  necessary  to 
safely  handle  the  liquid.  Obtain  a  material 
safety data sheet (MSDS) for the liquid to be 
sure these precautions are understood.
failure  to  follow  above  listed  precaution-
ary measures may result in serious injury or 
death.