Canon WX6000 用户手册

下载
页码 240
161
Setting Up the Projector
Installation Manual
Installation
Area where lens movement is not possible
With the Standard Zoom Lens, Long Zoom Lens and Ultra Long Zoom Lens, when the 
shift exceeds 44% in the upward direction, the amount of available shift in the left / right 
directions decreases. When the lens is shifted upward to the maximum (1), the amount of 
available shift in the left / right direction is ±2%.
With the Short Fixed Lens, greater shift in the up / down direction reduces the available 
shift in the left / right direction. When the lens is shifted upward or downward to the maxi-
mum, shift in the left / right direction is not possible.
90°
At maximum rightward lens shift
90°
At maximum leftward lens shift
(3)
Amount movable in 
left/right direction
2% of projected 
image width
2% of projected 
image width
44% of projected 
image height
(1)
Shift range
Projected 
image
Area where 
shift is not 
possible
2% of projected 
image width
2% of projected 
image width
Area where shift 
is not possible
Shift range
Projected 
image
5% of 
project-
ed image 
height
5% of 
project-
ed image 
height