Toshiba 3511 用户手册

下载
页码 552
November 2003  ©  TOSHIBA TEC
3 - 43
e-STUDIO3511/4511 ADJUSTMENT
3.7.9   Fine adjustment of black density
The density of black side on scanned image is adjusted at color-scanning.
Note:
Be careful for the value not to be too large since the gradation is reproduced worse in darker side.
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in the codes and press the [START] button.
(3)
Key in the adjustment values. Acceptable values : 0 to 4. (To correct the value once keyed in,
press [CLEAR] button.)
(4)
Press the [ENTER] or [INTERRUPT] button to store the value in memory.  
→ The equipment
goes back to the ready state.
(5)
Let the equipment restart and perform scanning job.
(6)
If the desired image has not been attained, repeat step (1) to (5).
3.7.10   RGB conversion method selection
The color space conversion method of image is decided at color-scanning.
Code
1075
1076
1077
Original mode
Text
Printed Image
Photo
Remarks
The larger the value is, the black side of the image becomes darker.
Acceptable values: 0 to 4 (Default: 0)
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in the codes and press the [START] button.
(3)
Key in the adjustment values. Acceptable values : 0 to 3. (To correct the value once keyed in,
press [CLEAR] button.)
(4)
Press the [ENTER] or [INTERRUPT] button to store the value in memory.  
→  The equipment goes
back to the ready state.
(5)
Let the equipment restart and perform scanning job.
(6)
If the desired image has not been attained, repeat step (1) to (5).
Code
1080
1081
1082
Original mode
Text
Printed Image
Photo
Remarks
0: sRGB     1: AppleRGB     2: ROMMRGB     3: AdobeRGB
(Default: 0)
<Adjustment Mode (05)>
<Adjustment Mode (05)>