e-STUDIO3511/4511 ADJUSTMENT
3 - 60
November 2003  ©  TOSHIBA TEC
0.5mm–0.3
0mm
3.12.2  Adjustment of RADF height
It is mainly performed at the installation. It is also required when the RADF is dislocated for some reason
such as moving the equipment.
Perform the following adjustment by using the screw of the left and right hinge.
Note:
Perform this adjustment after “3.12.1 Adjustment of RADF position”.
Turn the exposure lamp ON during the gap check. (Test Mode: 03-267)
Adjustment standard:
Adjust the height so that the platen guide front holder touches the ADF original glass.
Adjust the height so that the gap between the platen guide rear holder and the ADF original glass
becomes 0.5 mm ± 0.3.
Adjust the height by turning the height adjusting
screw on the right hinge.
Clockwise: The height of the hinge becomes high.
Counterclockwise: The height of the hinge becomes
low.
Adjust the height by turning the height adjusting
screw on the left hinge.
Clockwise: The height of the hinge becomes high.
Counterclockwise: The height of the hinge becomes
low.
Platen guide
front holder
ADF original glass
Platen guide
rear holder
Fig. 3-1213
Fig. 3-1214
Fig. 3-1215