System Guide
1- 11
Gateway and Network Configuration
Although the default is set so that the SNMP locality and unit of 
measure is the same as that of the LUI, the new feature allows the 
administrator to select a different locality or unit of measure for the 
SNMP gateway.
Remote SNMP clients can control the localization of text objects 
of syntax 
LocalizedDescriptionStringTC by setting the MIB object:
prtGeneralCurrentLocalization
Access is changed from Read-only to Read/Write. 
However, Remote SNMP clients cannot control the units of 
measure localization of numeric MIB objects. The localization of 
these objects can only be controlled from the LUI.
SNMP configuration variables
Of the many parameters that are available for SNMP 
configuration, only the ones of common interest to Xerox 
customers are shown in the following table:
Table 1-2  
Configuration Variables
Parameter Name
Description
Value 
Range
Default 
Value
CommandLine
Turn on/off the following flags:
–l: logging to SNMP_DEBUG_LOG
–w: logging to window
Printer operator
The name of the printer operator
String 
(0...127)
<empty>
Printer administrator
The name of the printer administrator
String 
(0...127)
<empty>
Printer administrator 
location
The location of the office of the printer 
administrator
String 
(0...127)
<empty>
Printer administrator 
Phone
The telephone number for contacting the 
printer administrator
String 
(0...127)
<empty>
Printer location
The location of the printer
String 
(0...127)
<empty>