Philips 5900 用户手册
Management and Configuration
AXIS 5900 User’s Manual
101
You select your desired conversion filter by setting the Character Set
Conversion (PRx_CSET) parameter. The output from the conversion filter
is always IBM PC Set 2 (Code Page 437), and this is the character set the
printer must be set up for.
Example:
Your network contains a host using the character set ISO 8859-2. In order
to direct its print jobs to the printer connected to the Axis Network Print
Server, you should assign the host to a separate logical printer, and install
a character set conversion filter.
Follow the instructions below to change the conversion filter:
1. From the print server’s internal Web page, select
Admin | Logical Printer
Settings.
2. Select the
PR1 tab.
3. Set the parameter
Physical Port to LPT1.
4. Set the parameter
Character Set Conversion to ISO>IBM.
5. Click the
OK button.
6. Select the
Printer2 tab.
7. Set the parameter
Physical Port to LPT1.
8. Set the parameter
Character Set Conversion to DEC>IBM.
9. Click the
OK button.
The ISO 8859-2 printer data that is sent to logical printer PR1 converts to
IBM PC Set 2 and is printed on LPT1. Similarly, the DEC printer data that
is sent to logical printer PR2 converts to IBM PC Set 2 and is printed on
LPT1.
Adding Strings Before
and After Print Jobs
These string functions provide a way to send printer control commands
before and after each print job. They may be specified individually for
each logical printer.
All strings are entered as hexadecimal byte values.
Example:
Your network contains a host using the character set ISO 8859-2 and a host
using the character set DEC. In order to direct their print jobs to the printer
connected to the Axis Network Print Server, you should assign each host to a
separate logical printer, and install a character set conversion filter.
using the character set DEC. In order to direct their print jobs to the printer
connected to the Axis Network Print Server, you should assign each host to a
separate logical printer, and install a character set conversion filter.
Assume that the logical printer PR5 is configured as a PostScript printer and
that you want to append the PostScript End of File character (hex
that you want to append the PostScript End of File character (hex
04
) after
each print job.