Lexmark 4069-XXX 用户手册

下载
页码 376
Diagnostic Information
2-79
4069-XXX
No indication that Bin X is Full OR No indication that Bin X is Near 
Full
High-Capacity Output Stacker Service Check
Service Tip: The majority of the mechanical components can be 
observed during operation by removing the left, right and front 
covers. The high capacity output stacker option functions without the 
covers installed.
Models 010 and 010n do not support this output option.
Determine which paper path stacker assembly is not functioning 
properly.
Make sure the option(s) are installed correctly and the machine is 
configured correctly before attempting to service the high-capacity 
output stacker option.
Go to 
 to identify the 
correct jumper location at J6 for the upper and lower units.
FRU
Action
1
Dual Output Bin X Sensor 
Assembly
Control Board
Check for correct installation of 
the sensor cable at J5 on the 
control board. If either the Bin Full 
(F) or Bin Near Full (NF) fail the 
sensor test then check the voltage 
at J5-3 and J5-4. The voltage 
measures approximately +5 V dc. 
If the voltage is incorrect, replace 
the control board. If correct, 
replace the sensor assembly.