Lexmark 4069-XXX 用户手册

下载
页码 376
Diagnostic Information
2-47
4069-XXX
Fuser Service Check
Hot Roll Fuser
Cold Fuser Service Check
Error codes 920, 921, and 922 may display for a cold fuser failure. A 
920 error caused by low line voltage can sometimes be cleared by 
turning the machine off and then on again. A 925 service error 
indicates the wrong fuser lamp is installed in the printer and does not 
match the one stored in the printer code.
Note:  Make sure the fuser is correctly installed before proceeding 
with this service check. The fuser must be firmly seated in the two 
rear connectors. Both the right and left lock down screws must be 
tight.
Service Tip: Set the Fuser Temperature to NORMAL before starting 
this service check.
3
Error Code 927 (Fan runs)
Check the voltage at J1-1 on the 
engine board. The voltage measures 
+5 V dc (static) 0 V dc (fan running). 
If incorrect, replace the main fan. If 
this does not fix the problem, replace 
the engine board. 
4
Error Code 927
(Fan not running)
Check the voltage at J1-3 on the 
engine board. The voltages are as 
follows:
+22 V dc to +24 V dc 
(printer and fan running)
+12 V dc to +15 V dc 
(printer not running - fan running 
about half speed).
If incorrect, replace the engine 
board. If this does not fix the 
problem, replace the main fan. 
FRU
Action