IBM Type 7977 用户手册

下载
页码 124
Microprocessor
 
problems
 
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
on
 
the
 
IBM
 
System
 
x
 
Documentation
 
CD
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Symptom
 
Action
 
The
 
server
 
emits
 
a
 
continuous
 
beep
 
during
 
POST,
 
indicating
 
that
 
the
 
startup
 
(boot)
 
microprocessor
 
is
 
not
 
working
 
correctly.
 
1.
   
Correct
 
any
 
errors
 
that
 
are
 
indicated
 
by
 
the
 
light
 
path
 
diagnostics
 
LEDs
 
(see
 
 
2.
   
Make
 
sure
 
that
 
the
 
server
 
supports
 
all
 
the
 
microprocessors
 
and
 
that
 
the
 
microprocessors
 
match
 
in
 
speed
 
and
 
cache
 
size.
 
3.
   
(Trained
 
service
 
technician
 
only)
 
Reseat
 
Microprocessor
 
1
 
4.
   
(Trained
 
service
 
technician
 
only)
 
If
 
there
 
is
 
no
 
indication
 
of
 
which
 
microprocessor
 
has
 
failed,
 
isolate
 
the
 
error
 
by
 
testing
 
with
 
one
 
microprocessor
 
at
 
a
 
time.
 
5.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
(Trained
 
service
 
technician
 
only)
 
microprocessor
 
2
 
b.
   
VRM
 
2
 
c.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
6.
   
(Trained
 
service
 
technician
 
only)
 
If
 
there
 
are
 
multiple
 
error
 
codes
 
or
 
light
 
path
 
diagnostics
 
LEDs
 
that
 
indicate
 
a
 
microprocessor
 
error,
 
reverse
 
the
 
locations
 
of
 
two
 
microprocessors
 
to
 
determine
 
whether
 
the
 
error
 
is
 
associated
 
with
 
a
 
microprocessor
 
or
 
with
 
a
 
microprocessor
 
socket.
 
v
   
If
 
the
 
error
 
is
 
associated
 
with
 
a
 
microprocessor,
 
replace
 
the
 
microprocessor.
 
v
   
If
 
the
 
error
 
is
 
associated
 
with
 
a
 
VRM,
 
replace
 
the
 
VRM.
 
v
   
If
 
the
 
error
 
is
 
associated
 
with
 
a
 
microprocessor
 
socket,
 
replace
 
the
 
system
 
board.
  
Monitor
 
problems
 
Some
 
IBM
 
monitors
 
have
 
their
 
own
 
self-tests.
 
If
 
you
 
suspect
 
a
 
problem
 
with
 
your
 
monitor,
 
see
 
the
 
documentation
 
that
 
comes
 
with
 
the
 
monitor
 
for
 
instructions
 
for
 
testing
 
and
 
adjusting
 
the
 
monitor.
 
If
 
you
 
cannot
 
diagnose
 
the
 
problem,
 
call
 
for
 
service.
 
 
82
 