Zebra Technologies Z4Mplus 用户手册

下载
页码 178
Troubleshooting
Printer Diagnostics
Z4Mplus and Z6Mplus User Guide 
111
Feed Self Test 
See the illustration at right.
Perform the following procedure 
to complete the Feed Self Test:
1. Turn the printer Off (
O
).
2. Press and hold FEED while turning the 
printer On (
l
).
3. Release FEED after the DATA light turns 
off (approximately five seconds).
Feed Self Test prints out at various darkness 
settings above and below that of the darkness 
value shown on the configuration label. 
Examine these labels and determine which one 
has the best darkness setting for your 
application. This value can be entered into the 
printer by setting the darkness during the 
configuration procedure. See 
 for more 
information.
The value printed on that label is added to (plus) or subtracted from (minus) the 
darkness value specified on the configuration label. The resulting numeric value 
(0 to 30) is the best darkness value for that specific media and ribbon combination.