Motorola MVME2600 用户手册

下载
页码 198
A-2
Computer Group Literature Center Web Site
Specifications
A
Cooling Requirements
The Motorola MVME2603/2604 family of single board computers is 
specified, designed, and tested to operate reliably with an incoming air 
temperature range from 0° to 55° C (32° to 131° F) with forced air cooling 
of the entire assembly (base board and modules) at a velocity typically 
achievable by using a 100 CFM axial fan. Temperature qualification is 
performed in a standard Motorola VME system chassis. 25-watt load 
boards are inserted in two card slots, one on each side, adjacent to the 
board under test, to simulate a high power density system configuration. 
An assembly of three axial fans, rated at 100 CFM per fan, is placed 
directly under the VME card cage. The incoming air temperature is 
measured between the fan assembly and the card cage, where the incoming 
airstream first encounters the module under test. Test software is executed 
as the module is subjected to ambient temperature variations. Case 
temperatures of critical, high power density integrated circuits are 
monitored to ensure component vendors’ specifications are not exceeded.
While the exact amount of airflow required for cooling depends on the 
ambient air temperature and the type, number, and location of boards and 
other heat sources, adequate cooling can usually be achieved with 10 CFM 
and 490 LFM flowing over the module. Less airflow is required to cool the 
module in environments having lower maximum ambients. Under more 
favorable thermal conditions, it may be possible to operate the module 
reliably at higher than 55° C with increased airflow. It is important to note 
that there are several factors, in addition to the rated CFM of the air mover, 
which determine the actual volume and speed of air flowing over a 
module.