Proper Grounding
http://www.motorola.com/computer/literature
B-9
B
Proper Grounding
An important subject to consider is the use of ground pins. There are two 
pins labeled GND. Pin 7 is the signal ground and must be connected to the 
distant device to complete the circuit. Pin 1 is the chassis ground, but it 
must be used with care. The chassis is connected to the power ground 
through the green wire in the power cord and must be connected to be in 
compliance with the electrical code.
The problem is that when units are connected to different electrical outlets, 
there may be several volts of difference in ground potential. If pin 1 of each 
device is interconnected with the others via cable, several amperes of 
current could result. This condition may not only be dangerous for the 
small wires in a typical cable, but may also produce electrical noise that 
causes errors in data transmission. That is why 
 
show no connection for pin 1. Normally, pin 7 (signal ground) should only 
be connected to the chassis ground at one point; if several terminals are 
used with one computer, the logical place for that point is at the computer. 
The terminals should not have a connection between the logic ground 
return and the chassis.