Troubleshooting
Solving Startup Problems
In the event of difficulty with your MVME5100, perform the simple 
troubleshooting steps listed in the table below before calling for help or 
sending the board back for repair.
Some of the procedures will return the board to the factory debugger 
environment. It is important to note that the Board was tested under these 
conditions before it left the factory. The self-tests may not run in all user-
customized environments.
Table B-1.  Troubleshooting Problems
Condition
Possible Problem
Possible Resolution:
I. Nothing works;
no display on the 
terminal.
A. If the LEDs are not 
lit, the board may 
not be getting 
power.
1. Make sure the system is plugged in.
2. Check that the board is securely installed in its 
backplane or chassis.
3. Check that all necessary cables are connected to the 
board.
4. Review the Installation and Startup procedures in this 
manual. They include a step-by-step powerup routine.
B. If the LEDs are lit, 
the board may be 
in the wrong slot.
1. The MVME5100 should be in the first (leftmost) slot.
2. Check if the “system controller” function on the board 
is enabled per the instructions this manual.
C. The “system 
console” terminal 
may be configured 
incorrectly.
Configure the system console terminal per the instructions 