Brady 200M-e 300 用户手册

下载
页码 118
42
Bradyprinter 200M-e and 200M-e 300 User’s Guide
&KDQJLQJ3DVVZRUG3URWHFWHG3DUDPHWHUV
Certain parameters are password-protected by factory default. 
CAUTION:  Do not change password-protected parameters 
unless you are sure you know what you are doing!  If the 
parameters are set incorrectly, they could cause the printer to 
function in an unpredictable way.
The first attempt to change one of these parameters (pressing either the (+) 
or (–) key) requires you to enter a four-digit password.  This is done via the 
“ENTER PASSWORD” display.  The (–) key changes the selected digit 
position; the (+) key increases the selected digit value.  After entering the 
password, press the NEXT/SAVE key.  The parameter you wish to change 
is displayed.  If the password was entered correctly, you can now change 
the value.
The default password value is 1234.  The password can be changed using 
the 
^KP
 (Define Password) ZPL II instruction or through BradyConnect 
when the appropriate print server is used.
NOTE:  Once the password has been entered correctly, it does not 
have to be entered again unless you leave and re-enter the 
programming mode using the SETUP/EXIT key.
NOTE:  You can disable the password protection feature so that it 
no longer prompts you for a password by setting the password to 
ØØØØ via the 
^KPØ
 ZPL/ZPL II  command.  To re-enable the 
password-protection feature, send the ZPL/ZPL II command 
^KPx
where “x” can be any number, one to four digits in length,
except Ø.