Brady 200M-e 300 用户手册

下载
页码 118
Bradyprinter 200M-e and 200M-e 300 User’s Guide
77
3ULQWHU'LDJQRVWLFV
3RZHU2Q6HOI7HVW
A limited Power-On Self Test (POST) is performed automatically each 
time the printer is turned on (additional self tests can be performed by 
pressing the CANCEL key when you turn the printer on).  During either 
test sequence, the front panel lights and liquid crystal display (LCD) 
monitor the progress of the POST.  If the printer fails any of these tests, the 
word “FAILED” is added to the display.  If this occurs, notify an 
authorized Brady distributor.
$GGLWLRQDO3ULQWHU6HOI7HVWV
These self tests produce sample printouts and provide specific information 
that help determine the operating conditions for the printer.
Each self test is enabled by pressing a specific front panel key or 
combination of keys while turning the POWER switch on.  Keep the 
key(s) depressed until the DATA light turns off.  When the Power-On Self 
Test is complete, the selected self test starts automatically.
NOTES:  When performing self tests, avoid sending a label format 
to the printer.  In the case of a remote host, disconnect all data 
interface cables from the printer.
When canceling a self test prior to its actual completion, always 
turn the printer power off and then back on to reset the printer.
When performing these self tests while in the Peel-Off mode, you 
must remove the labels as they become available.
If your media is not wide enough or long enough, unexpected     
and/or undesired results may occur.  Make sure that your print 
width is set correctly for the media you are using before you run any 
self tests, otherwise the test may print out on the platen roller.  See 
page 46 for information on setting the print width.