Brady 3000 用户手册

下载
页码 87
Printer-Applicator-System PAM 3000
44
13 Operation
Positioning of the Labels
The labels could be applied parallel to the print line (0°-position) as well as across to the print
line (90°-position).  An external signal via PLC interface triggers the type of labelling (see
appendix C).  The take-over of the labels is carried out in the 0°-position for both types of
applying.  The following movements are different :
0°-Applying
1. Turning into the 90°-position
2. Moving down
3. Stop
4. Turning into the 0°-position
5. Moving down
6. Applying
7. Moving up
8. Stop
9. Turning into the 90°-position
10. Moving up
11. Turning into the 0°-position
90°-Applying
1. Turning into the 90°-position
2. Moving down
3. Stop
4. not any movement
5. Moving down
6. Applying
7. Moving up
8. Stop
9. not any movement
10. Moving up
11. Turning into the 0°-position
Fig. 13a Sensors
The stop is set during the movement process to guarantee a correct carrying out of the turning
of the pad.  The location of the stop depends on the setting of the sensors (1, 2).  During the
90°-applying the stop is not recognized by the user.
2
1