Status indicators
Replacing the battery
Warnings:
• Read and follow the Important Safety Instructions before 
servicing the battery. Service the battery under the supervision of 
personnel knowledgeable of batteries and their precautions.
• Use only the specified type of battery. See your dealer for 
replacement batteries.
• The battery may present a risk of electrical shock. Do not dispose 
of battery in a fire because it may explode. Follow all local 
ordinances regarding correct disposal of batteries. Almost any 
retailer that sells lead-acid batteries collects used batteries for 
recycling, as required by most state laws.
• Do not open or damage the batteries. The batteries contain 
electrolytes that are harmful to skin and eyes.
• A battery can present a high risk of short circuit current and 
electrical shock. Take the following precautions before replacing 
the battery:
• Remove all watches, rings, or other metal objects.
• Only use tools with insulated handles.
• Do not lay tools or metal parts on top of the battery or any 
terminals.
• Wear rubber gloves and boots.
• Determine if the battery is inadvertently grounded. If 
grounded, remove the source of ground. Contact with a 
grounded battery can result in electrical shock.
To replace the battery:
Turn off and unplug all connected devices.
Turn the UPS off and unplug it from the AC power source.
Turn the UPS upside down.
Remove the retaining screw.
Slide the battery compartment cover completely off of your UPS.
Remove the battery from the compartment.
Disconnect the battery wires from the battery. Note which wire is 
connected to the positive (+) and negative (–) terminals of the 
battery.
Install the replacement battery by connecting the red wire and 
black wire to the positive (+) and negative (–) terminal of the 
battery.
Put the battery back into the compartment.
10 Slide back the battery compartment cover and tighten the 
retaining screw.
11 Recharge your UPS for 4 - 8 hours to fully charge the battery.
Warning: Batteries are consider hazardous waste and must be disposed 
of correctly. Almost any retailer that sells lead-acid batteries collects 
used batteries for recycling, as required by most state laws.
Off
Off
Long 
beep
System Overload–The amount 
of power required by plugged 
in devices exceeds the amount 
of power your UPS can supply. 
Turn off your UPS, unplug at 
least one device, wait 10 
seconds, reset the circuit 
breaker, then turn on your UPS.
Off
On/Off
Long 
beep
Battery Overload–The amount 
of power required by devices 
plugged into the 
battery-powered outlets 
exceeds the amount of power 
the battery can supply. Turn the 
UPS off, unplug at least one 
device from battery-powered 
outlets, wait 10 seconds, reset 
the circuit breaker, then turn on 
your UPS.
On/Off
On
None
Electrical Wiring Fault–The AC 
outlet your UPS is plugged into 
has a wiring problem, such as a 
bad ground, a missing ground, 
or reversed wiring. Contact an 
electrician to repair the outlet or 
use a different outlet.
Power 
On
P
Wiring 
Fault