Emerson AXP1600 用户手册

下载
页码 148
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records
SAM Physical Shelf Manager Analog Sensors
32
   
2.3.5.2
Temperature Sensors
The following tables describe the analog temperature sensors available on the physical SAM.
Settable threshold mask (bytes 
19, 20)
0x12, 0x12
Upper and Lower Critical 
Thresholds are Readable and 
Settable
Reading Type
Unsigned
Lower critical threshold
0x00
0 Volts
Upper critical threshold
0xFF
15.81 Volts
Table 2-7 Sensor No. 5 +1.8 V
Feature
Raw Value/Description
Interpreted Value
Sensor Name
+1.8 V
Type of measurement
Voltage
Device
Sensor Type
0x02
Voltage
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0xF0
PICMG Shelf Management 
Controller
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
No
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask, 
Settable threshold mask (bytes 
19, 20)
0x10, 0x10
Upper Critical Threshold is 
Readable and Settable
Reading Type
Unsigned
Upper critical threshold
0xFF
2.499 Volts
Table 2-6 Sensor No. 4 +12 V Voltage (continued)
Feature
Raw Value/Description
Interpreted Value
Table 2-8 Sensor No. 6 MAX6656 INT@1A
Feature
Raw Value/Description
Interpreted Value
Sensor Name
MAX6656 INT @1A
Device
Sensor Type
0x01
Temperature
Class
0x01
Threshold