110V aC eleCtriCal DeViCe example run-time Chart
Appliance type
estimated Wattage
estimated time*
Spotlights, Sump Pumps, DVD 
Players
100 Watts
1.3 hours
Faxes, tVs, Small Power tools
150 Watts
50 Minutes
Computer Printer, Medium Power 
tools, Blenders
200 Watts
40 Minutes
The maximum continuous load is 400 watts. 
*note: Estimated run-times. Actual time may vary. Times are based on the internal 
battery being fully charged.
PoWeRIng A 110V AC DeVICe
There are two-110 volt AC POWER outlets 
located on the front panel.
To operate a 110 volt AC device:
1.  Make sure the device to be powered 
is OFF.
2.   Plug the 110V AC device power cord 
into a AC POWER outlet located on 
the front panel. Push the INVERTER 
switch  located  on  left  side  of  front 
panel  to  ON  (I).  The  digital  display 
will show 0. 
3.   Turn  ON  the  110V  AC  device.  The 
digital display will show the draw of 
watts from device plugged in.
4.   If a device will not operate properly 
when first connected to the inverter, 
push  the  INVERTER  rocker  switch 
ON (I), OFF (0), and ON (I) again in 
quick  succession.  If  this  procedure 
is not successful, it is likely the PP-
18400CI inverter does not have the 
required  capacity  to  operate  the 
device(s) in question. Make sure the 
wattage does not exceed 400.
5.   Turn OFF (0) the INVERTER switch 
when finished.
6.   Charge the PP-18400CI as soon as 
possible after each use.
CAUTION:  Incorrect  operation  of  your 
inverter  may  result  in  damage  and  per-
sonal  injury.  Electrical  current  on  a  110 
volt circuit can be very dangerous.
tRoUBleShootIng the InVeRteR 
1.  Alarm sounds, and device plugged 
in shuts off.
 
Continuous load demand or wattage 
exceeds 400 watts. Push INVERTER 
switch to the OFF (0) position.
 
Determine source of problem, and re-
solve it before reusing the inverter.
2.  the Alarm Sounds. 
 
Voltage  from  the  internal  battery 
drops  to  approximately  10.5  volts. 
When the power input drops to ap-
proximately  11  volts  an  alarm  will 
sound for an extended period.
3.  Inverter shuts down. 
 
The PP-18400CI inverter temperature 
exceeds 145º F. 
 
NOTE: The PP-18400CI is fitted with 
a cooling fan that runs continuously 
for loads drawing 25 watts or higher. 
If  cooling  fan  is  unable  to  maintain 
a cool enough temperature for safe 
operation, inverter will automatically 
shut  down.  If  inverter  automatically 
shuts down or a continuous audible 
alarm  is  heard,  push  INVERTER 
switch to the OFF (0) position. Deter-
mine source of problem, and resolve 
it before reusing the inverter.