Users Manual & Installation Guide  
                            PV- 5127: 
Power supply module with UPS 
 
 
Page 13 of 31 
Note that the heater and fan outputs are logical outputs that become 3.3V when they are active.  If 
necessary, the user must provide driving circuitry to drive an actual heater and fan.  The positions of 
the two outputs in CN2 are shown here. 
 
 
 
 
If the temperature is too cold or too hot, the CPU cannot be turned on until it changes to cool or 
warm.  But if it the CPU is on, and the temperature later changes to too cold or too hot, the CPU 
continues running. 
 
If the temperature changes to too hot and you are using UPS monitoring software with the RS232 
status signals, a “critical alarm” (mains failure and low battery) is signalled, prompting the 
monitoring software to shut down immediately.  UPS monitoring software that reads status 
information through the PC/104 can also detect this condition and react accordingly.