Panasonic PT-CW240E 用户手册

下载
页码 74
Maintenance/replacement
56
 - ENGLISH
Maintenance
Clean the air filters.
4 ) 
Vacuum dirt and dust from the air filters.
 
z
Install the air filters. 
5 ) 
To install the air filters, reverse the previous steps until you hear a "click" sound.
 
z
Reset the [Filter Reminder].
6 ) 
Turn on the power and perform [Cleaning up Reminder] in the [Options] menu. 
 
z
(
Æ
page 44)
Attention
Turn off the power before you clean the air filters.
 
z
Be sure to attach the air filters properly. If you use the projector without attaching the air filters, the projector may be 
 
z
damaged due to the dirt or dust.
Note
If the air filter has been damaged or dust / dirt can not be removed, please replace it with a new filter.
 
z
The <TEMP> indicator lights up and the warning temperature message displays because of clogging within 500 hours, 
 
z
depending on the using environment. In that case, clean the air filter at short intervals.
If the spacer (detachable) of the adjustable feet is overlapping at removing the air filter (rear), rotate the spacer with 
 
z
grabbing the knob of the spacer to keep a clearance from the air filter (rear).
Air filter (rear)
Space (detachable)
Air filter (side)
Bottom View
Adjust feet (Rear)