Optoma Technology EP739 用户手册

下载
页码 3
 
 
To further enhance the viewing experience of the audience – more precise commands 
are added to minimize the disruption during a source change. 
 
Furthermore, to avoid confusion with old RS232 commands and possible software 
maintenance problem the silent OSD are implemented using new RS232 commands. 
The side benefit of this implementation is user choose silent OSD or non-silent OSD 
just by invoking different RS232 commands 
 
IR 030     
source lock on 
IR 031     
source lock off 
IR 032n    
source select    n=1 is DVI-D 
 
 
 
 
n=2 is DVI-RGB (*1) 
 
 
 
 
n=3 is DVI-YPbPr (*1) 
 
 
 
 
n=4 is D-sub RGB 
 
 
 
 
n=5 is D-sub YPbPr (include 480i, 480p, 720p, 1080i, 576i, 576p) 
 
 
 
 
n=6 is D-sub SCART 
 
  n=7 is RCA YPbPr (include 480i, 480p, 720p 1080i, 576i, 
576p)
(*2)
 
 
 
 
 
n=8 is composite 
 
 
 
 
n=9 is S-video 
IR 033n   
aspect ratio 
n=1 is 4:3 
 
 
 
 
n=2 is 16:9 
 
 
 
 
n=3 is window = 4:3 inside 16:9 
 
 
 
 
n=4 is letterbox 
IR 034nn brightness 
nn= 00-99, 99 is the brightest 
IR 035nn contrast   
nn=00-99, 99 is highest contrast 
IR 036nn volume   
nn=00-99, 99 is loudest 
IR 037nn zoom 
 
nn=0-31, 31 is maximum zoom 
IR 038n   
color temperature n=1 is low 
 
 
 
 
n=2 is medium 
 
 
 
 
n=3 is high 
New read commands (not related to silent mode) 
ID ?        returns    ID x       
x= any unique ID such as serial no. 
Hour?    returns     “
HR nnnn\r”
  nnnn= lamp hours in 4 digits   
 
*1: select to DVI 
*2: Not support