DMC-1400  Series Command Reference AO 
● 23   
AO
 
FUNCTION:  Analog Out 
DESCRIPTION: 
The AO command sets the analog output voltage of Modbus Devices connected via Ethernet.  
ARGUMENTS:  AO m, n  
where 
m is the I/O number calculated using the following equations: 
 
m = (SlaveAddress*10000) + (HandleNum*1000) + ((Module-1)*4) + (Bitnum-1) 
Slave Address is used when the Modbus device has slave devices connected to it and  
specified as 
Addresses 0 to 255.  Please note that the use of slave devices  
for Modbus are very rare and this number will usually be 0. 
HandleNum is the handle specifier from A to F (1 to 6).   
Module is the position of the module in the rack from 1 to 16.   
BitNum is the I/O point in the module from 1 to 4. 
 
n = the voltage which ranges from 9.99 to –9.99 
USAGE:     
While Moving 
Yes 
Default Value 
--- 
In a Program 
Yes 
Default Format 
--- 
Command Line 
Yes 
 
 
Controller Usage 
DMC-1415/1416/1425 
RELATED COMMANDS: 
Set Bit 
Clear Bit 
EXAMPLES: