DMC-1400  Series Command Reference BZ 
● 47   
BZ   
 
 
 
FUNCTION:  Brushless Zero 
DESCRIPTION: 
The BZ command is when the controller is configured for sinusoidal commutation.  This 
command drives the motor to zero magnetic phase and then sets the commutation phase 
to zero. 
This command may be given when the motor is off. 
ARGUMENTS:  BZ x 
where  
x is a real number between -9.998 and 9.998. 
The parameter x sets the voltage to be applied to the amplifier during the initialization.  In 
order to be accurate, the BZ command must be large enough to move the motor.  When 
the argument is positive, the process ends up in MO state.  A negative value causes the 
process to end up in the SH state. 
Note:  The BZ command causes instantaneous movement of the motor.  It is recommended to 
start with small voltages and increase as needed. 
Note:  Always use the Off-On-Error function (OE Command) to avoid motor runaway 
whenever testing sinusoidal commutation. 
USAGE:     
While Moving 
No 
Default Value 
In a Program 
Yes 
Default Format 
Command Line 
Yes 
 
 
Can be Interrogated 
No 
 
 
Used as an Operand 
No 
 
 
Controller Usage 
DMC-1412/1415/1410/1417 
OPERAND USAGE: 
_BZ contains the distance in encoder counts from the motor's current position and the position 
of commutation zero.  This can useful to command a motor to move to the commutation 
zero position for phase initialization. 
EXAMPLES: 
BZ -3 
Drive the motor to zero phase position with 3 volts signal, and end up in 
SH state. 
RELATED COMMANDS: 
BA  
Brushless Axis 
BB  
Brushless Phase Begins 
BC  
Brushless Commutation 
BD  
Brushless Degrees