3.2.3. 
Network error detection (c100 - c103c523
▼Display of trip information 
err8
 (Optional unit fault 1: 1BH): Network error stop 
 
▼Related parameter 
Title Function 
Setting 
range 
Description 
c100 
Communication error 
detection delay time 
0.0-100.0 sec 
The waiting time from when a network error occurs 
can be adjusted. If a network error continues past 
the time set in c100, it is recognized as a 
communication error and the operation of the 
inverter follows the setting of c101. 
When normal communication returns during the 
setting time, a communication error is not displayed 
and operation is continued. 
 
*The case of Modbus
®
 TCP protocol 
The time-out detection time provides by c523 
parameter. 
Disconnection detection time =   
c523
 (Time out) +   
c100
 (
Communication error detection delay time
)
 
*The case of EtherNet/IP
TM
 protocol 
-At I/O scanning and connected communication 
  Time-out time =   
RPI 4 2
Connection Timeout Multiplier
 [μs] + c100 
(communication error detection delay time) [0.1s]
RPI: Request Packet Interval 
 
-At Unconnected communication 
Time-out is not operating. 
c101 
Inverter operation at the 
communications loss action 
0-5 
The operation of the inverter when the 
communication fault occurs can be specified. 
c102 
Preset speed operation 
selection 
1-15 
The operation frequency of the inverter when the 
communication fault occurs can be specified. (Only 
when c101 is set to 5) 
c103 
Communication time-out 
condition selection 
0-2 
Select the communication time-out condition. 
c523 
Time out 
0.0: Disable 
0.5 - 60 sec. 
The waiting time from the occurrence of the 
network error to detection can be adjusted. 
* When you are using unconnected communication 
of the EtherNet/IP protocol, time-out is not 
detected.