Cabletron Systems STS16-20D 用户手册

下载
页码 258
145
Switch Configuration
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
inactive
Disabled
stop
Transient state during enable/disable
idle
Both primary and traced port down
groupPortDown
Primary port down
tracedPortDown
Traced port down
active
Operational
stopOnError
Error condition. Check the Message Log. Then disable the
group, correct the error and enable the group again.
Group Priority
Whenever more than one switch is able to take over from a failed switch, the one with 
the highest priority will be chosen. Possible values are 0255, the default is 100.
Hello Time
Interval between hello packets sent by DSRR for this group. Possible values are 
100
600,000 milliseconds, the default is 500.
Hold Time
If no hello packets are received from a switch for this group within the interval 
specified here, the switch will be declared failed. Possible values are 100600,000 
milliseconds, the default is 1,700.
Traced Port
Identification of the (virtual ATM) port connected to the emulated (or other legacy) 
Token-Ring. When you select this item, you will be prompted for a box (stack only) 
and port number. If the value(s) entered identifies an ATM Trunk Port, a list of 
CRFs configured on this port are displayed. Select one. See Figure 27 on page 142.
Backup for Primary Port
Identifies a port for forwarding traffic that has been taken over from a failed switch. 
This port must be connected to the same legacy Token Ring as the port that 
identifies (together with Group Id) the DSRR group that is being configured. See 
Figure 27. on page 142.
Backup for Traced Port
Identifies a backup port for forwarding traffic that has been taken over from a failed 
switch. If the Traced Port is a Virtual ATM Port, the backup port must be able to 
join the same emulated Token-Ring as the Traced Port. Otherwise it must be 
connected to the same ring as the Traced Port. See Figure 27. on page 142.