Cabletron Systems STS16-20D 用户手册

下载
页码 258
187
Monitoring the Network from the Console Statistics Menu
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
A CRF that does not connect to other switches or bridges is always forwarding.
When the switch is booted, all CRFs are blocked initially, and then some of 
them change to a different state: listening, learning, and forwarding, in that 
order. All CRFs that are going to change states from blocking to forwarding 
will have done so after two to three times the value of:
Switch Maximum Message Age + (2 x Switch Forward Delay)
DCst (Designated Cost)
Cost for a packet to travel from this CRF to the root in the current spanning tree 
configuration. The slower the media, the higher the cost.
Dsg SwId/BrId (Designated Switch Id/Bridge Id)
Priority and ID of the device through which this port has determined it must 
communicate with the root of the spanning tree. A BRF will use the base MAC 
address + 0x20 for the ID. The first defined CRF will use the base MAC 
address + 0x21 for the ID, etc.
Dsg PId (Designated Port Id)
Port on the designated bridge through which this SmartStack STS16-20D/STS16-
20R will communicate with the root of the spanning tree. This information is useful 
if the SmartStack STS16-20D/STS16-20R is the designated bridge on one or more 
network segments.
# Chgs
Number of topology changes, that is, the number of times the CRF has entered the 
forwarding state plus the number of times the CRF has made the transition from 
forwarding to blocking. The counter is reset when the switch is reset or the 
spanning tree is turned on.
Last Chg
Time since the CRF last entered the forwarding state or made the transition from 
forwarding to blocking.
You cannot change any information on this screen. To change the spanning tree 
parameters, refer to the section “Spanning Tree for BRF Screen” on page 99.