Workgroup Remote Access Switch      61
O
RDERING
 ISDN S
ERVICE
 (US O
NLY
)
Ordering BRI ISDN Lines using Provisioning Settings
N
ORTHERN
 T
ELECOM
 DMS100 C
USTOM
 S
ERVICE
Note that you must set either EKTS or ACO to yes. You may not set both of them to yes.
B
ASIC
 I
NFORMATION
 
FOR
 O
RDERING
 PRI ISDN L
INES
ISDN Primary Rate is a communications service that allows the system to make up to 23 
connections over a single line. It uses a 4-wire T1 line that carries 24 channels, each providing 64000 
bps bandwidth. The service uses channels 1 to 23 as bearer (B) channels to carry connections 
between two systems. The 24th channel is used for signaling information (the data link).
The customer should request the following options for a Primary Rate Line that is connected 
directly to a CyberSWITCH:
B8ZS encoding
ESF framing
all channels should be Circuit Switched Data
Hunt Group (if desired)
call bandwidth supported (56Kbps, 64Kbps, and/or 384Kbps)
 CLID (calling line Id); usually there is no charge for this
In order to connect to the Primary Rate line, the customer needs a Channel Service Unit (CSU), 
which is now integrated into the CyberSWITCH. If the line is provided by a LEC or IXC, the CSU 
is required by the phone company to protect the phone network from any problems with customer 
Northern Telecom DMS100 Custom Service
Provisioning Element
Setting
signaling
functional
PVC
1
TEI assignment
dynamic
maxkeys
3 is preferable
1-64 is acceptable
release key
no
ringing indicator
no
EKTS
no
ACO
yes
number of call 
appearances
2
LCC
ISDNKSET
version
functional
CS
yes
PS
no