Cabletron Systems 2E48-27R 用户手册

下载
页码 160
Installing the Device
2E48-27R/2E49-27R User’s Guide
3-7
3.3.3
Connecting Power to the 2E4X-27R 
To connect the 
2E4X-27R
 to the power sources, proceed as follows: 
1.
. To 
take advantage of the load sharing and redundancy capabilities, each 
power cord must be plugged into a dedicated ac outlet. The POWER 
LED turns ON (green) and the CPU LED turns ON (green) briefly.
Figure 3-5
2E4X-27R Rear View
2.
Observe the LANVIEW LEDs. After a successful boot, the CPU LED 
turns ON (green). If the CPU LED is not green after one minute and 
turning amber, there is no power redundancy. Check the power cord 
connections and the power source. If there are no problems with the 
power cord connections or power source and the CPU LED is still not 
green, contact the Cabletron Systems Global Call Center. Refer to 
 for details.
NOTE
The 2E4X-27R has two power supplies with automatic voltage 
sensing that allows connection to power sources ranging from 
100–125 Vac or 200–250 Vac, 50/60 Hz. 
NOTE
It takes approximately one minute for the 2E4X-27R to boot up.
Primary
Redundant
2E48-27R
2314-62