FE Switch Module User Guide
Page B-1
APPENDIX B
CABLES 
B.1 TYPES/CONNECTORS
Depending on the type of switch module you are using, you’ll need to use 
specific cables, as described in the IEEE 802.3u specification, shown in 
the table below.
B.2 CABLE SPECIFICATIONS
Table B-1
Cable Types and Connectors
Cable
Type
Male Connector
Twisted-Pair 
(UTP)
100 Ohm UTP,
22 - 26 AWG
0.4 - 0.6 mm,
2 pairs
8-pin RJ45
Duplex Fiber
62.5/125 Micron Core
ST
Table B-2
Twisted-Pair Cable Specifications
Type
Type 5 balanced UTP
Number of Pairs
2
Max. Link Segment Length
328 ft (100 m)
Min. Link Segment Length
2.0 ft (0.6 m)
Max. Number of Attachments
2
Table B-3
Duplex Fiber Cable Specifications
Type
62.5/125 micron core multimedia fiber
Max. Link Segment Length
1.24 mi (2.0 Km)
Min. Link Segment Length
No minimum size
Max. Number of Attachments
2