DSXH43GVWW—GE 6.0 Cu. Ft. Capacity Spacemaker
®
Gas Dryer
GE Appliances
Specification Revised 6/00
Dryer Dimensions (in inches)
Dryer Installation Options
Exhaust Options:
Gas—3-way via rear, right and bottom. Dryer is shipped exhausted to the rear. Alternate
exhausting knockouts are supplied.
Gas—3-way via rear, right and bottom. Dryer is shipped exhausted to the rear. Alternate
exhausting knockouts are supplied.
Gas Dryer Electric Rating: 120V, 60Hz, 6A
An individual properly-grounded branch circuit, with a three-prong grounding-type receptacle,
protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required.
An individual properly-grounded branch circuit, with a three-prong grounding-type receptacle,
protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required.
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply
requires a conversion kit. Check installation instructions for correct kit and have a qualified
gas technician install a conversion kit. See dryer ducting information for proper installation.
requires a conversion kit. Check installation instructions for correct kit and have a qualified
gas technician install a conversion kit. See dryer ducting information for proper installation.
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible
when dryer is mounted in position.
when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed
with your dryer.
with your dryer.
REAR VIEW
26-7/8
3-3/4
1
36
Under
Counter
34-5/8"
3/16"
Gas Pipe Connection
Electric
Connection
Connection
2-9/16
13-9/16
SIDE VIEW
25-3/4
47-1/2
4-3/4
Optional
Vent Knockout
Vent Knockout
Door Open
90
°
4-3/8
3/4
27" Min.
27" Min.
70-5/8
Note:
27"
Min.
34-5/8"
Min.
Custom Sized
Countertop Required
Countertop Required
54" Min.
27 Min.
Note:
Closet Installation Requires Additional
Minimum Clearances:
Closet Installation Requires Additional
Minimum Clearances:
A Minimum of 120 Square Inches of Openin
Equally Divided at the Top and Bottom of
the Closet Door is Required.
Equally Divided at the Top and Bottom of
the Closet Door is Required.
Top of Dryer to Ceiling
15"
Back of Dryer to Wall
4"
Front of Dryer/Washer
1"
to Closet Door
R
Listed by
Underwriters
Laboratories
Underwriters
Laboratories