National Instruments 1128 用户手册

下载
页码 97
Chapter 1
Installing and Configuring the SCXI-1127/1128
© National Instruments Corporation
1-9
Figure 1-5.  12-Slot Configuration Parts Locator Diagram
1.
Install the 8-slot HVAB-backplane adapter behind slots 5 through 12.
2.
Install additional 2-slot and 1-slot HVAB-backplane adapters behind 
slots 1 through 4 if needed.
3.
Install the 8-position HVAB plugs to connect the HVAB-backplane 
adapters as needed.
4.
Connect the HV8-BAN4 cable from the DMM to the HVAB connector 
behind slot 12.
5.
Connect the SH9MD-9MD cable from the DMM to the AUX IN 
connector behind slot 5.
6.
You can install any additional SCXI-1127 modules in any slot that has 
an HVAB-backplane adapter behind it.
Notes
Do not connect the SH9MD-9MD cable to the AUX IN connector behind slot 4 on 
the 2-slot HVAB-backplane adapter.
An SCXI-1127/1128 is required in slot 12 to establish communications with the chassis. 
If slot 12 is empty, the system will not operate. It is this module that you must specify in 
MAX as the module cabled to the DMM.
1
8-Slot HVAB-Backplane Adapter
2
HV8-BAN4 Cable
3
8-Position HVAB Plug
4
2-Slot HVAB-Backplane Adapter
5
1-Slot HVAB-Backplane Adapter
6
NI 4060 for PCI
7
SH9MD-9MD Cable
8
12-Slot SCXI Chassis
AB0+
AB0–
AB2+
AB2–
6
8
7
1
3
2
4
5