Appendix D     Register-Level Programming
PC-LPM-16/PnP User Manual
D-4
 
 
 National Instruments Corporation
 
Command Register 1
 
Command Register 1 indicates the input channel to be read and the interrupt enable bits.
 
Address:
 
Base address + 00 (hex)
 
Type:
 
Write-only
 
Word Size:
 
8-bit
 
Bit Map:
 
 
 
Bit
Name
Description
 
7
SCANEN*
Scan Enable Bit—This bit enables or disables 
multichannel scanning during data acquisition. The 
power-on value is 1. If this bit is cleared, analog 
channels MA<3..0> through 0 are sampled 
alternately. If this bit is set, a single analog channel 
selected by MA<3..0> is sampled during the entire 
data acquisition operation. In order to perform single-
channel sampling, the UP/DOWN bit in Command 
Register 2 must be clear before setting SCANEN* to 
1. To set up a scanning mode, two consecutive 
writings of this register are necessary. First, write the 
desired valve to the UP/DOWN bit in Command 
Register 2 if the UP/DOWN bit is not currently set to 
its proper value. Then write MA<3..0> with 
SCANEN* set to load the scan counter. Then write 
MA<3..0> with SCANEN* cleared to enable 
scanning. 
For example, if the UP/DOWN bit is 0 and MA<3..0> 
is 0011 and SCANEN* is first set, then cleared, analog 
input channels 3 through 0 are sampled alternately 
during subsequent data conversions. If SCANEN* is 
set and is not cleared (with MA<3..0> still set to 
0011), only analog input channel 3 is sampled during 
the subsequent data conversions.
See the 
 
 
more information.
 
7
6
5
4
3
2
1
0
SCANEN*
CNTINTEN
EXTINTEN
FIFOINTEN
MA3
MA2
MA1
MA0
 
a.Book : l.Appendix D  Page 4  Wednesday, November 20, 1996  6:36 PM