National Instruments 6024E 用户手册

下载
页码 136
Appendix A
Specifications for PCI and PXI Buses
© National Instruments Corporation
A-5
FIFO buffer size ..................................... None
Data transfers ......................................... DMA, interrupts,
programmed I/O
DMA modes ........................................... Scatter-gather
(Single transfer, demand transfer)
Accuracy Information
Transfer Characteristics
Relative accuracy (INL)
After calibration .............................. ±0.3 LSB typ, ±0.5 LSB max
Before calibration ........................... ±4 LSB max
DNL
After calibration .............................. ±0.3 LSB typ, ± 1.0 LSB max
Before calibration ........................... ±3 LSB max
Monotonicity .......................................... 12 bits, guaranteed after
calibration
Offset error
After calibration .............................. ±1.0 mV max
Before calibration ........................... ±200 mV max
Gain error (relative to internal reference)
After calibration .............................. ±0.01% of output max
Before calibration ........................... ±0.75% of output max
Nominal Range (V)
Absolute Accuracy
Absolute
Accuracy at
Full Scale
(mV)
% of Reading
Offset (mV)
Temp Drift
(%/ °C)
Positive FS
Negative FS
24 Hours
90 Days
1 Year
10
–10
0.0177
0.0197
0.0219
5.93
0.0005
8.127